Text NOTAM production rules
...
NAV.TD.operationalStatus | Corresponding Q codes (4th and 5th letters) |
---|---|
UNSERVICEABLE | AS |
ONTEST | CT |
INTERRUPT | LS |
PARTIAL | AS |
FALSE_INDICATION | XX |
DISPLACED | CM |
IN_CONSTRUCTION | XX |
OTHER | XX |
Scope
Insert here AE.
Items B, C and D
...
Reference | Rule | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(1) | The name of the Navaid shall be included if present in the NAV.BL data | ||||||||||||||||||||||||||||||||||||||||
(2) | Insert the type from the Navaid baseline, according to the following decoding rule:
| ||||||||||||||||||||||||||||||||||||||||
(3) | If the Navaid Baseline has several Navaid components and only one of its primary component NavaidEquipment has a NEQ.TD associated with the Event, then insert the type of that equipment, according to the following decoding rule:
| ||||||||||||||||||||||||||||||||||||||||
(4) | If NAV.BL is TACAN or VORTAC and its (TACAN)TD.availability.signalType is specified, then insert its value here. | ||||||||||||||||||||||||||||||||||||||||
(5) | The following rules apply:
| ||||||||||||||||||||||||||||||||||||||||
(6) | Apply the following rules:
| ||||||||||||||||||||||||||||||||||||||||
(7) | Apply the following rules:
| ||||||||||||||||||||||||||||||||||||||||
(8) | Insert the NEQ.TD.operationalStatus decoded as follows:
| ||||||||||||||||||||||||||||||||||||||||
(9) | If specified, insert here only the NEQ.TD.NavaidOperationalStatus.annotation that has propertyName="operationalStatus" and purpose="REMARK", translated into free text according to the following encoding rules. | ||||||||||||||||||||||||||||||||||||||||
(10) | Annotations shall be translated into free text according to the rules for annotations decoding. |
...
The eventual update of this type of event shall be encoded following the general rules for {{Event updates update or cancellation}}, which provide instructions for all NOTAM fields, except for item E and the condition part of the Q code, in the case of a NOTAM C
If a NOTAM C is produced, then the 4th and 5th letters (the "condition") of the Q code shall be "AK", except for the situation of a “new NOTAM to follow", in which case “XX”shall be used.
The following pattern should be used for automatically generating the E field text from the AIXM data:
Code Block | ||||
---|---|---|---|---|
| ||||
template_cancel = ["NAV.BL.name(1)"] "NAV.BL.type(2)" ["NEQ.BL.type(3)"]\n [( "NAV.BL.designator(5)" | "RWY-" "NAV.BL.runwayDirection(5)")] \n ["NEQ.BL.frequency(6)"] ["NAV.BL.channel(7)"] ("resumed normal operations""."\n | [" : New NOTAM to follow(11)"]). |
Reference | Rule |
---|---|
(11) | If the NOTAM will be followed by a new NOTAM concerning the same situation, then the operator shall have the possibility to specifychoose the "New NOTAM to follow" and this text shall be appended at the end of item E of the NOTAM Cbranch. This branch cannot be selected automatically because this information is only known by the operator. Note: in this case, the 4th and 5th letters of the Q code shall also be changed into “XX”. |